{"title":"TOPDRIVE® VFD (EMC) ROZ1-K (AS)","description":"\u003cp\u003eTOPDRIVE® VFD (EMC) ROZ1-K (AS) cable has been specially \u003cbr\u003edesigned for Variable Frequency Drive Motors and installations\u003cbr\u003ewhere it is necessary to limit the effects of electromagnetic\u003cbr\u003einterference (EMI). This is a flexible cable for fixed installations, for\u003cbr\u003evariable speed motors or pumps\u003c\/p\u003e","products":[{"product_id":"topdrive-emc-3x6-3g1-5mm","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x6+3G1.5mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x6+3G1.5mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eAt 3x6+3G1.5mm² this is the smallest three-phase-plus-symmetrical-earth formation in the TOPDRIVE range, sized for short drive-to-motor runs on conveyors, small pumps and packaging machinery where the drive is mounted close to the load but EMI still has to be contained.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468848632056,"sku":"2003006JNEMC","price":13.49,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003006JNEMC_1_cbb7bff5-ea0f-43ce-9f39-f14c919ee705.jpg?v=1789436541"},{"product_id":"topdrive-vsd-emc-roz1-k-as-4g2-5mm2","title":"TOPDRIVE VFD (EMC) ROZ1-K 4G2.5mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 4G2.5mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 4G2.5mm² formation covers small motor and pump circuits — dosing pumps, small conveyors and extraction fans — where a screened cable is required to keep drive switching noise off adjacent signal cabling.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eFour-core formation — the protective conductor is the same cross-section as the phase conductors, cabled helically with them.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The four-core construction pairs a full-section protective conductor with the same 100% double screen used across the TOPDRIVE range.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468946149624,"sku":"2004002MNEMC","price":7.08,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2004002MNEMC_1_b4f72925-2354-4a13-95c7-d52507e33d42.jpg?v=1789436604"},{"product_id":"topdrive-vsd-emc-roz1-k-as-4g6-0mm2","title":"TOPDRIVE VFD (EMC) ROZ1-K 4G6mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 4G6mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 4G6mm² four-core formation handles general-purpose motor circuits across industrial plant, and is the smallest four-core TOPDRIVE size covered by the Cca reaction-to-fire classification.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575).\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eFour-core formation — the protective conductor is the same cross-section as the phase conductors, cabled helically with them.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The four-core construction pairs a full-section protective conductor with the same 100% double screen used across the TOPDRIVE range.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468946968824,"sku":"2004006GNEMC","price":13.4,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2004006GNEMC_1_a2a70a4c-dd39-42e5-a853-c8df41566c82.jpg?v=1789436710"},{"product_id":"topdrive-emc-3x10-3g1-5mm-black","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x10+3G1.5mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x10+3G1.5mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 3x10+3G1.5mm² formation suits mid-duty motor circuits on water treatment and HVAC plant — enough phase capacity for a typical 4–7.5kW drive while keeping the three symmetrically distributed earth conductors that cancel common-mode current back to the drive.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468947067128,"sku":"2003010JNEMC","price":19.56,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003010JNEMC_1_4deb245a-ada3-497f-8501-9ab308e17d9e.jpg?v=1789436744"},{"product_id":"topdrive-emc-3x25-3g4-0mm","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x25+3G4mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x25+3G4mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 3x25+3G4mm² formation handles larger process drives — mixers, compressors and booster pump sets — where cable runs lengthen and reflected-wave voltage peaks at the motor terminals become the limiting factor on insulation life.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575), Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468947853560,"sku":"2003025JNEMC","price":45.9,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003025JNEMC_1_de698f0e-8595-443f-84d1-0a756dd3b957.jpg?v=1789437439"},{"product_id":"topdrive-emc-3x150-3g25mm-1kv","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x150+3G25mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x150+3G25mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 3x150+3G25mm² formation is specified for major drive feeders on infrastructure and heavy industrial projects — tunnel ventilation plant, primary process drives and large water pumping stations.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575), Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468948967672,"sku":"2003150JNEMC","price":246.78,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003150JNEMC_1_00aacacb-35d4-4406-90b7-588360d558b3.jpg?v=1789437475"},{"product_id":"topdrive-vsd-emc-roz1-k-as-4g1-5mm2","title":"TOPDRIVE VFD (EMC) ROZ1-K 4G1.5mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 4G1.5mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 4G1.5mm² formation is the entry size for screened drive cable — actuators, small fans and HVAC dampers where the motor is fractional but sits on the same bus as sensitive instrumentation.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eFour-core formation — the protective conductor is the same cross-section as the phase conductors, cabled helically with them.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The four-core construction pairs a full-section protective conductor with the same 100% double screen used across the TOPDRIVE range.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468949393656,"sku":"2004001MNEMC","price":5.32,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2004001MNEMC_1_7ef5d12a-88e4-4442-a13b-569421c831f1.jpg?v=1789437500"},{"product_id":"topdrive-zh-roz1-k-emc-black-0-6-1kv-4g4","title":"TOPDRIVE VFD (EMC) ROZ1-K 4G4mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 4G4mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 4G4mm² four-core formation puts the earth conductor on the same cross-section as the phases, suiting compact drive installations and machine builds where a conventional four-core layout is specified but EMC screening is still required.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eFour-core formation — the protective conductor is the same cross-section as the phase conductors, cabled helically with them.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The four-core construction pairs a full-section protective conductor with the same 100% double screen used across the TOPDRIVE range.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468949917944,"sku":"2004004GNEMC","price":9.86,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2004004GNEMC_1_95ee7a98-6f07-46c1-8884-55e2a4159644.jpg?v=1789437564"},{"product_id":"topdrive-zh-roz1-k-emc-3x16","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x16+3G2.5mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x16 Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eAt 3x16mm² phase section this formation covers the step up into larger pump and fan drives, and is the smallest TOPDRIVE size carrying marine type approval for shipboard and offshore installations.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468949950712,"sku":"2003016JNEMC","price":29.08,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003016JNEMC_1_270f5332-55a8-4446-8ec3-78f9bf04784f.jpg?v=1789437625"},{"product_id":"topdrive-zh-roz1-k-emc-3x95-3g16-1kv","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x95+3G16mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x95+3G16mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThe 3x95+3G16mm² formation is a large-motor feeder — primary drives on crushing plant, main ventilation fans and high-head pump stations — where the tinned copper braid over aluminium-polyester tape maintains full screen coverage across long, high-current runs.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575), Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468950278392,"sku":"2003095JNEMC","price":157.16,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003095JNEMC_1_992561d5-3d29-49c7-b7b5-c7a2ae08887f.jpg?v=1789437661"},{"product_id":"topdrive-zh-roz1-k-emc-4g10-0-6-1kv-black-cca","title":"TOPDRIVE VFD (EMC) ROZ1-K 4G10mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 4G10mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eAt 4G10mm² this is the largest four-core TOPDRIVE formation, sized for drive panels feeding mid-range motors where a full-section earth is preferred over the symmetrical three-earth arrangement.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575).\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eFour-core formation — the protective conductor is the same cross-section as the phase conductors, cabled helically with them.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The four-core construction pairs a full-section protective conductor with the same 100% double screen used across the TOPDRIVE range.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468950376696,"sku":"2004010GNEMC","price":21.24,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2004010GNEMC_1_46b8aaac-50be-4965-ac80-ec4f23770d5e.jpg?v=1789437687"},{"product_id":"topdrive-vfd-emc-roz1-k-3x50-3g10","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x50+3G10mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 50mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eThis size sits in the heavy-feeder band of the TOPDRIVE range, intended for large motor and pump drives on industrial and infrastructure sites.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468950638840,"sku":"2003050JNEMC","price":90.93,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003050JNEMC_1_e01040f8-764f-467a-ba9f-4574c88f819c.jpg?v=1789437869"},{"product_id":"topdrive-zh-roz1-k-emc-3x35-3g6-1kv-black-cca","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x35+3G6mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x35+3G6mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eAt 3x35+3G6mm² this size serves heavy process and materials-handling drives, including tunnel ventilation fans and mine site conveyor heads where LSZH construction is a specification requirement rather than a preference.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575), Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468950933752,"sku":"2003035JNEMC","price":64.81,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003035JNEMC_1_894360ac-0e93-4be7-bfd9-1fc305c06b4d.jpg?v=1789437833"},{"product_id":"topdrive-zh-roz1-k-emc-3x120-3g16-1kv-black-cca","title":"TOPDRIVE VFD (EMC) ROZ1-K 3x120+3G16mm² Screened Flex Cable","description":"\u003ch2\u003eTOPDRIVE VFD (EMC) ROZ1-K 3x120+3G16mm² Screened Flex Cable\u003c\/h2\u003e\u003cp\u003eAt 3x120+3G16mm² this size feeds the largest variable-speed drives on a typical industrial site, where the cost of unplanned motor bearing replacement far exceeds the cable premium over an unscreened alternative.\u003c\/p\u003e\u003ch3\u003eFeatures and Specifications\u003c\/h3\u003e\u003cp\u003eStandards (\u0026amp; Conformities): IEC 60502-1, IEC 60092-353, CE, RoHS, CPR Cca-s1a,d1,a1 (EN 50575), Bureau Veritas, ABS, DNV-GL, Lloyd's Register.\u003c\/p\u003e\u003ch4\u003eConductor:\u003c\/h4\u003e\u003cp\u003eElectrolytic annealed copper, class 5 flexible, to EN 60228 \/ IEC 60228.\u003c\/p\u003e\u003ch4\u003eProtective Conductor:\u003c\/h4\u003e\u003cp\u003eThe earth is divided across three conductors distributed symmetrically in the interstices between the phase conductors, giving a balanced impedance path so common-mode currents cancel rather than returning through motor bearings.\u003c\/p\u003e\u003ch4\u003eInsulation:\u003c\/h4\u003e\u003cp\u003eCross-linked polyethylene (XLPE) to IEC 60502-1, type HF XLPE 90°C to IEC 60092-360. XLPE's lower dielectric constant reduces capacitive coupling under the fast voltage transitions a variable frequency drive produces.\u003c\/p\u003e\u003ch4\u003eScreen:\u003c\/h4\u003e\u003cp\u003eAluminium-polyester tape applied helically over the insulated conductors, with a tinned copper braid over the tape. Tape and braid act as a double screen with 100% coverage and a minimum total section of 10% of the phase conductor. A ripcord allows the outer sheath to be opened without damaging the screen.\u003c\/p\u003e\u003ch4\u003eOuter Sheath:\u003c\/h4\u003e\u003cp\u003ePolyolefin type ST8 to IEC 60502-1 and type SHF1 to IEC 60092-360, black. Low smoke zero halogen — low corrosive gas emission to IEC 60754-2 and light transmittance above 80% to IEC 61034.\u003c\/p\u003e\u003ch4\u003eInstallation:\u003c\/h4\u003e\u003cp\u003eFixed installations — open air, buried or in conduit. Minimum bending radius 10x cable diameter; impact resistance AG2 (medium severity); UV resistant to EN 50618; water resistance AD5 (jets).\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eApplications:\u003c\/strong\u003e Variable frequency drive motors and pumps, industrial facilities, and tunnels and enclosed infrastructure where low smoke zero halogen construction is mandatory. The 3C+3G symmetrical configuration with 100% double screen is the arrangement recommended by leading VFD manufacturers and the Gambica Association.\u003c\/p\u003e\u003cp\u003e\u003cbr\u003e\u003ci\u003eNote: Please choose product carefully. Product selection is the responsibility of the Purchaser. Refer to relevant Standards, project requirements and technical specifications to ensure that the product meets requirements.\u003c\/i\u003e\u003c\/p\u003e","brand":"Top Cable","offers":[{"title":"Default Title","offer_id":50468951294200,"sku":"2003120JNEMC","price":191.64,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2003120JNEMC_1_524a02bb-5f68-483b-a637-edbae97f90d3.jpg?v=1789437801"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/collections\/TOPDRIVE_VFD_FeaturedImage_v1.webp?v=1789447539","url":"https:\/\/www.tropac.co.nz\/collections\/topdrive-vfd-emc.oembed","provider":"TROPAC","version":"1.0","type":"link"}