{"title":"Energy Meters","description":"","products":[{"product_id":"energy-meter-em120-rtu-2p-1-3-phase-5a-ct-connect-pulse-output-modbus-rtu-1","title":"1–3 Phase Energy Meter CT Input, Modbus RTU","description":"\u003cp\u003eThe Weidmüller EM120-RTU-2P is a versatile energy meter capable of operating in both single-phase and three-phase CT configurations. Supporting primary currents up to 5000A via external current transformers, it is suited to sub-metering medium and large loads in commercial and industrial installations. Active energy measurement meets Class 1 accuracy per IEC 62053-21.\u003c\/p\u003e\u003cp\u003eThe meter connects to BMS and SCADA platforms via RS485 Modbus RTU, and includes a pulse output for energy signal integration. An LCD display provides local readout, and the unit mounts on standard TS35 DIN rail with a 72mm profile. Operating temperature range is -25°C to +55°C.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203120378104,"sku":"7760051004","price":236.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051004_1.jpg?v=1776775672"},{"product_id":"energy-meter-em122-rtu-2p-1-3-phase-100a-direct-pulse-output-modbus-rtu-1","title":"1–3 Phase Energy Meter 100A Direct, Modbus RTU","description":"\u003cp\u003eThe Weidmüller EM122-RTU-2P is a single\/three-phase energy meter with direct connection rated to 100A — no external current transformer required. It is designed for sub-metering distribution boards in commercial and industrial buildings, measuring active energy to Class 1 accuracy (IEC 62053-21) and communicating via RS485 Modbus RTU.\u003c\/p\u003e\u003cp\u003eThe meter supports both single-phase and three-phase circuit configurations from a single device, simplifying product selection. An LCD display provides local energy and power readings, and a pulse output is included for integration with pulse-counting inputs on third-party systems. Mounts on standard 72mm TS35 DIN rail.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203230150904,"sku":"7760051003","price":247.86,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051003_1.jpg?v=1776775668"},{"product_id":"energy-meter-em124-rtu-2l-3-phase-dual-channel-5a-ct-pulse-output-modbus-rtu-1","title":"Dual-Load 3-Phase Energy Meter CT Input, Modbus RTU","description":"\u003cp\u003eThe Weidmüller EM124-RTU-2L is a multifunction power meter that simultaneously measures two separate three-phase circuits — replacing what would otherwise require two individual meters. It has been engineered specifically for split load distribution boards in commercial buildings where power and lighting circuits must be measured independently to support NABERS or equivalent energy efficiency ratings.\u003c\/p\u003e\u003cp\u003eThe EM124-RTU-2L uses innovative plug-and-play 3-phase current transformer (CT) blocks that connect back to the meter via a simple RJ12 cable, eliminating the risk of CT wiring errors. Measured parameters include V, A, W, VA, VAR, PF, THD, frequency, kWh, and demand. RS485 Modbus RTU supports daisy-chain connection of up to 64 devices. CT options (125A, 150A, 250A) are available separately.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203279007992,"sku":"2866030000","price":399.18,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2866030000_1.jpg?v=1776775224"},{"product_id":"current-transformer-cma-3p21-250-0-1a-0-5-3-phase-250-0-1a-class-0-6","title":"3-Phase Panel CT 250A \/ 0.1A, Class 0.5","description":"\u003cp\u003eThe Weidmüller CMA-3P21-250-0.1A-0.5 is a 3-phase current transformer block designed to work with the EM124-RTU-2L dual input multifunction power meter. All three phases are captured in a single block, and the RJ12 plug-and-play connection to the energy meter eliminates individual CT wiring and reduces installation errors.\u003c\/p\u003e\u003cp\u003eRated at 250A primary \/ 100mA secondary to Class 0.5 accuracy, with a 35mm centre pitch and 21×25mm conductor entry aperture. The included 0.5m flat ribbon RJ12 cable (150V insulation) is included; longer cables and higher insulation options are available separately. Suitable for DIN rail or panel mount.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203279073528,"sku":"2866060000","price":88.78,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2866060000_1.jpg?v=1776775230"},{"product_id":"energy-meter-em110-rtu-2p-1-phase-5a-ct-connect-pulse-output-modbus-rtu-1","title":"Single-Phase Energy Meter, CT Input, Modbus RTU","description":"\u003cp\u003eThe Weidmüller EM110-RTU-2P is a compact single-phase energy meter designed for use with external current transformers (CT), supporting primary currents up to 5000A. It measures active energy to Class 1 accuracy (IEC 62053-21) and connects to building management and SCADA systems via RS485 Modbus RTU communications. The narrow 17.5mm DIN rail profile makes it ideal for space-constrained switchboard installations.\u003c\/p\u003e\u003cp\u003eKey features include a backlit LCD display, two pulse outputs for energy pulse signalling, selectable Modbus addressing (1–247), and an operating temperature range of -25°C to +55°C. The front panel carries an IP51 ingress protection rating, suitable for indoor panel environments.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203281367288,"sku":"7760051002","price":182.96,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051002_1.jpg?v=1776775668"},{"product_id":"energy-meter-em111-rtu-2p-1-phase-45a-direct-pulse-output-modbus-rtu-1","title":"Single-Phase Energy Meter 45A Direct, Modbus RTU","description":"\u003cp\u003eThe Weidmüller EM111-RTU-2P is a compact single-phase direct-connection energy meter rated to 45A. Requiring no external current transformer, it is ideal for sub-metering individual circuits in commercial and light industrial buildings. Active energy measurement is Class 1 accurate to IEC 62053-21, and the meter communicates via RS485 Modbus RTU for integration with BMS, SCADA, and energy management platforms.\u003c\/p\u003e\u003cp\u003eThe EM111-RTU-2P features a backlit LCD display, a pulse output for energy signalling, selectable Modbus addressing, and a 17.5mm DIN rail profile for easy switchboard installation. Operating temperature range is -25°C to +55°C.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203281400056,"sku":"7760051001","price":121.97,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051001_1.jpg?v=1776775668"},{"product_id":"current-transformer-cma-3p21-125-0-1a-0-5-3-phase-125-0-1a-class-0-6","title":"3-Phase Panel CT 125A \/ 0.1A, Class 0.5","description":"\u003cp\u003eThe Weidmüller CMA-3P21-125-0.1A-0.5 is a 3-phase current transformer block designed to work with the EM124-RTU-2L dual input multifunction power meter. All three phases are captured in a single block, and the RJ12 plug-and-play connection to the energy meter eliminates individual CT wiring and reduces installation errors.\u003c\/p\u003e\u003cp\u003eRated at 125A primary \/ 100mA secondary to Class 0.5 accuracy, with a 35mm centre pitch and 21×25mm conductor entry aperture. The included 0.5m flat ribbon RJ12 cable (150V insulation) is included; longer cables and higher insulation options are available separately. Suitable for DIN rail or panel mount.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203281432824,"sku":"2866040000","price":83.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2866040000_1.jpg?v=1776775224"},{"product_id":"current-transformer-cma-3p21-150-0-1a-0-5-3-phase-150-0-1a-class-0-6","title":"3-Phase Panel CT 150A \/ 0.1A, Class 0.5","description":"\u003cp\u003eThe Weidmüller CMA-3P21-150-0.1A-0.5 is a 3-phase current transformer block designed to work with the EM124-RTU-2L dual input multifunction power meter. All three phases are captured in a single block, and the RJ12 plug-and-play connection to the energy meter eliminates individual CT wiring and reduces installation errors.\u003c\/p\u003e\u003cp\u003eRated at 150A primary \/ 100mA secondary to Class 0.5 accuracy, with a 35mm centre pitch and 21×25mm conductor entry aperture. The included 0.5m flat ribbon RJ12 cable (150V insulation) is included; longer cables and higher insulation options are available separately. Suitable for DIN rail or panel mount.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203281465592,"sku":"2866050000","price":85.08,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2866050000_1.jpg?v=1776775224"},{"product_id":"energy-meter-rcma-b22-d125-1-5-rogowski-coil-diameter-125-mm-cable-length-1-5-m-100-5000-a-output-mv-signal-1","title":"Rogowski Coil 125mm, 1.5m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D125-1.5 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 125mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 1.5m cable connects to the RCMC-5000-1A-P transducer, which converts the Rogowski signal to a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593380000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 125mm diameter; cable length 1.5m to RCMC transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203281989880,"sku":"2593380000","price":246.14,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593380000_1.jpg?v=1776775111"},{"product_id":"energy-meter-rcma-b22-d125-4-5-rogowski-coil-diameter-125-mm-cable-length-4-5-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 125mm, 4.5m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D125-4.5 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 125mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 4.5m cable connects to the RCMC-5000-1A-P transducer, which converts the Rogowski signal to a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593350000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 125mm diameter; cable length 4.5m to RCMC transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282022648,"sku":"2593350000","price":281.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593350000_1.jpg?v=1776775104"},{"product_id":"energy-meter-rcma-b22-d125-6-0-rogowski-coil-diameter-125-mm-cable-length-6-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 125mm, 6m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D125-6.0 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 125mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 6m cable provides extended reach for installations where the transducer must be mounted away from the primary conductor, and connects to the RCMC-5000-1A-P transducer to deliver a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e125 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2831100000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 125mm diameter; 6m cable provides extended reach to transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282055416,"sku":"2831100000","price":323.98,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2831100000_1.jpg?v=1776775211"},{"product_id":"energy-meter-rcma-b22-d175-1-5-rogowski-coil-diameter-175-mm-cable-length-1-5-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 175mm, 1.5m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D175-1.5 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 175mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 1.5m cable connects to the RCMC-5000-1A-P transducer, which converts the Rogowski signal to a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593390000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 175mm diameter; cable length 1.5m to RCMC transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282088184,"sku":"2593390000","price":281.32,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593390000_1.jpg?v=1776775111"},{"product_id":"energy-meter-rcma-b22-d175-4-5-rogowski-coil-diameter-175-mm-cable-length-4-5-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 175mm, 4.5m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D175-4.5 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 175mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 4.5m cable connects to the RCMC-5000-1A-P transducer, which converts the Rogowski signal to a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593360000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 175mm diameter; cable length 4.5m to RCMC transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282120952,"sku":"2593360000","price":298.91,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593360000_1.jpg?v=1776775104"},{"product_id":"energy-meter-rcma-b22-d175-6-0-rogowski-coil-diameter-175-mm-cable-length-6-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 175mm, 6m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D175-6.0 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 175mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 6m cable provides extended reach for installations where the transducer must be mounted away from the primary conductor, and connects to the RCMC-5000-1A-P transducer to deliver a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e175 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2831110000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 175mm diameter; 6m cable provides extended reach to transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282153720,"sku":"2831110000","price":339.7,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2831110000_1.jpg?v=1776775211"},{"product_id":"energy-meter-rcma-b22-d300-6-0-rogowski-coil-diameter-300-mm-cable-length-6-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 300mm, 6m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D300-6.0 is a Rogowski rope current transformer designed for accurate AC current measurement on large conductors up to 300mm in diameter — the largest coil in the RCMA-B22 range, suited to high-current mains feeds in data centres, substations, and major commercial installations. The flexible rope design clips around an energised conductor without disconnecting the primary circuit, and the 6m cable connects to the RCMC-5000-1A-P transducer to deliver a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2865880000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eLargest coil in the RCMA-B22 range — suits high-current mains up to 300mm conductor diameter\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282186488,"sku":"2865880000","price":464.38,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2865880000_1.jpg?v=1776775224"},{"product_id":"energy-meter-rcma-b22-d70-1-5-rogowski-coil-diameter-70-mm-cable-length-1-5-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 70mm, 1.5m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D70-1.5 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 70mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 1.5m cable connects to the RCMC-5000-1A-P transducer, which converts the Rogowski signal to a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e1.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593370000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 70mm diameter; cable length 1.5m to RCMC transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282219256,"sku":"2593370000","price":211.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593370000_1.jpg?v=1776775104"},{"product_id":"energy-meter-rcma-b22-d70-4-5-rogowski-coil-diameter-70-mm-cable-length-4-5-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 70mm, 4.5m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D70-4.5 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 70mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 4.5m cable connects to the RCMC-5000-1A-P transducer, which converts the Rogowski signal to a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593340000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 70mm diameter; cable length 4.5m to RCMC transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282252024,"sku":"2593340000","price":246.14,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593340000_1.jpg?v=1776775104"},{"product_id":"energy-meter-rcma-b22-d70-6-0-rogowski-coil-diameter-70-mm-cable-length-6-m-100-5000-a-output-pulse-mv-signal-1","title":"Rogowski Coil 70mm, 6m","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMA-B22-D70-6.0 is a Rogowski rope current transformer designed for accurate AC current measurement on conductors up to 70mm in diameter. Unlike traditional wound current transformers, the flexible rope design clips around an energised conductor without disconnecting the primary circuit — making it ideal for retrofitting into existing switchboards, substations, data centres, and commercial buildings. The 6m cable provides extra reach for installations where the transducer must be mounted away from the primary conductor, and connects to the RCMC-5000-1A-P transducer to deliver a standard 0–1A AC output compatible with any energy meter that accepts a 1A CT input.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Coil (Rope Current Transformer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMax Primary Current\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e5000 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCurrent Range (selectable)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e100–5000 A (12 ranges, set on RCMC transducer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eConductor Size (max Ø)\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e70 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCable Length\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e6.0 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003emV (via RCMC transducer: 0–1A AC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-10)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSaturation\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eNone — air core design\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProtection Rating\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eIP57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSuitable Applications\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eData centres, substations, commercial \u0026amp; industrial buildings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMandatory Accessory\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRCMC-5000-1A-P Transducer (Order No. 2593400000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2831090000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eClip-around rope design installs onto live conductors without circuit disconnection\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eNo saturation effect — accurate measurement of both small currents and high-frequency harmonics\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 to IEC 61869-10 — suitable for NABERS and sub-metering compliance\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eSuits conductors up to 70mm diameter; 6m cable provides extended reach to transducer\u003c\/li\u003e\n\u003cli\u003eWorks with any energy meter accepting a 1A CT input — pairs directly with Weidmüller EM energy meter range\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282284792,"sku":"2831090000","price":299.44,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2831090000_1.jpg?v=1776775211"},{"product_id":"energy-meter-rcmc-5000-1a-p-measuring-transducer-every-rogowski-coil-100-5000-a-output-0-1-a-ac-1","title":"Rogowski Transducer 0–1A, Class 0.5","description":"\u003cp style=\"font-family:Arial,sans-serif;font-size:15px;line-height:1.6;color:#111827;margin:0 0 16px\"\u003eThe Weidmüller RCMC-5000-1A-P is the signal converter required to complete a Rogowski coil measurement system. It accepts the mV output from any RCMA-B22 rope current transformer and converts it to a standard 0–1A AC signal, making the Rogowski coil output compatible with any energy meter that accepts a conventional 1A CT input. Twelve selectable current ranges from 100A to 5000A allow the transducer to be configured for a wide range of installation scenarios — from sub-distribution boards to high-current mains feeds up to 5000A.\u003c\/p\u003e\u003ctable style=\"width:100%;border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px\"\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eProduct Type\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eRogowski Transducer \/ Signal Converter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eCompatible With\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eAll RCMA-B22 Rogowski Coils (70mm, 125mm, 175mm, 300mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOutput Signal\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e0–1A AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eSelectable Current Ranges\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e12 ranges: 100, 200, 300, 400, 500, 750, 1000, 1500, 2000, 2500, 3000, 5000A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eAccuracy Class\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eClass 0.5 (IEC 61869-2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eLinearity Error\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e≤ 0.10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eOperating Temperature\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003e−25 to +70°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb;border-bottom:1px solid #e5e7eb\"\u003eMounting\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827;border-bottom:1px solid #e5e7eb\"\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"width:42%;padding:6px 10px;font-weight:600;color:#374151;background-color:#f9fafb\"\u003eOrder No.\u003c\/th\u003e\n\u003ctd style=\"padding:6px 10px;color:#111827\"\u003e2593400000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003cul style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;line-height:1.6;padding-left:20px;margin:0 0 16px\"\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eRequired accessory for all Weidmüller RCMA-B22 Rogowski coils — one RCMC per coil\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eConverts Rogowski mV output to 0–1A AC signal, compatible with any 1A CT energy meter input\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003e12 selectable ranges cover 100A to 5000A — suitable from sub-boards to high-current mains\u003c\/li\u003e\n\u003cli style=\"margin-bottom:4px\"\u003eAccuracy Class 0.5 (IEC 61869-2), linearity error ≤ 0.10%\u003c\/li\u003e\n\u003cli\u003eDIN rail mounted; operating temperature −25 to +70°C\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp style=\"font-family:Arial,sans-serif;font-size:14px;color:#374151;margin:0\"\u003eAvailable from TROPAC — contact our team for pricing and availability.\u003c\/p\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48203282317560,"sku":"2593400000","price":290.6,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/2593400000_1.jpg?v=1776775111"},{"product_id":"em220-rtu-4di2do-3-phase-energy-meter-with-modbus-rtu-4di-2do-1","title":"3-Phase Energy Meter with Modbus RTU, 4DI\/2DO","description":"\u003cp style=\"color:#111827;font-family:Arial,sans-serif;font-size:15px;line-height:1.6;margin:0 0 16px;\"\u003eThe EM220-RTU-4DI2DO is a panel-mount multifunction energy meter from Weidmüller's BasicLine range, designed for accurate power measurement in single-phase and three-phase installations. It connects to current transformers up to 5000 A primary and communicates measured values in real time via Modbus RTU over RS485 — making it well suited to switchboard builders, BMS integrators, and energy management applications where reliable sub-metering data is required. The built-in LCD display provides direct local readout of all key parameters without the need for an external tool or gateway.\u003c\/p\u003e\u003cfigure class=\"table\" style=\"margin-left:0;margin-right:auto;width:100%;\"\u003e\u003ctable style=\"border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eVoltage, current, active power, reactive power, apparent power, power factor, frequency, import\/export active and reactive energy, total system power demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eNetwork Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e1-phase 2-wire (L+N, L1+L2), 3-phase 3-wire (L1+L2+L3), 3-phase 4-wire (L1+L2+L3+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eVoltage Measurement Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e50–600 V AC (L-L) \/ 50–345 V AC (L-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCurrent Input\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eCT secondary 1 A or 5 A — supports up to 5000 A primary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eVoltage 0.5% \/ Current 0.5% \/ Active energy Class 0.5S (IEC 62053-22), Class 0.5 (IEC 61557-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCommunication Interface\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eRS485 — Modbus RTU (parity: none\/even\/odd; stop bits: 1 or 2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e4 digital inputs, 2 configurable digital outputs, pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eLCD — all measured parameters accessible on-unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e75–270 V AC \/ 100–380 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eFront panel IP51 \/ Rear IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eFront panel mount (DIN rail adapter available — EM220 BRACKET, 3068970000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e96 × 96 × 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e360 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e-25 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eScrew terminal — 0.5–2.5 mm² solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eRoHS compliant (with exemption 7a, 7cI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"color:#111827;padding:6px 10px;\"\u003e7760051005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cul style=\"color:#374151;font-family:Arial,sans-serif;font-size:14px;line-height:1.6;margin:0 0 16px;padding-left:20px;\"\u003e\n\u003cli\u003eClass 0.5S active energy accuracy per IEC 62053-22 — suitable for utility-grade sub-metering and energy auditing applications\u003c\/li\u003e\n\u003cli\u003eCT connection supports primary currents up to 5000 A — no need for direct high-current wiring into the meter\u003c\/li\u003e\n\u003cli\u003eModbus RTU over RS485 enables direct integration with SCADA, BMS, and energy management systems\u003c\/li\u003e\n\u003cli\u003e4 digital inputs and 2 configurable digital outputs for alarm, pulse counting, and load control functions\u003c\/li\u003e\n\u003cli\u003e96 × 96 mm front-panel form factor with optional DIN rail bracket (EM220 BRACKET, 3068970000) for flexible installation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48960811532536,"sku":"7760051005","price":310.52,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051005_1_95af0e14-99a6-4dc1-b5dd-35cc969c22d4.jpg?v=1781633008"},{"product_id":"em220-rtu-4di2do-gw-3-phase-energy-meter-with-modbus-rtu-tcp-ip-gateway-4di-2do-1","title":"3-Phase Energy Meter with Modbus RTU, TCP\/IP Gateway, 4DI\/2DO","description":"\u003cp style=\"color:#111827;font-family:Arial,sans-serif;font-size:15px;line-height:1.6;margin:0 0 16px;\"\u003eThe EM220-RTU-4DI2DO-GW is the gateway-enabled variant of Weidmüller's BasicLine energy meter, adding Modbus TCP\/IP over Ethernet to the standard RS485 Modbus RTU capability — making it the preferred choice where network-based energy monitoring or IT\/OT integration is required. Like the base model, it supports single-phase and three-phase measurement via CT connection up to 5000 A primary, with Class 0.5S accuracy and a full complement of 4 digital inputs and 2 digital outputs. The built-in gateway function means RS485 Modbus RTU devices downstream can be bridged onto an Ethernet network without additional hardware.\u003c\/p\u003e\u003cfigure class=\"table\" style=\"margin-left:0;margin-right:auto;width:100%;\"\u003e\u003ctable style=\"border-collapse:collapse;font-family:Arial,sans-serif;font-size:14px;margin:0 0 16px;\"\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMeasurement Parameters\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eVoltage, current, active power, reactive power, apparent power, power factor, frequency, import\/export active and reactive energy, total system power demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eNetwork Configuration\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e1-phase 2-wire (L+N, L1+L2), 3-phase 3-wire (L1+L2+L3), 3-phase 4-wire (L1+L2+L3+N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eVoltage Measurement Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e50–600 V AC (L-L) \/ 50–345 V AC (L-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCurrent Input\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eCT secondary 1 A or 5 A — supports up to 5000 A primary\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMeasurement Accuracy\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eVoltage 0.5% \/ Current 0.5% \/ Active energy Class 0.5S (IEC 62053-22), Class 0.5 (IEC 61557-12)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCommunication Interfaces\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eRS485 (Modbus RTU) + Ethernet (Modbus TCP\/IP Port 502 + Modbus Gateway)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eProtocols\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eModbus RTU, Modbus TCP\/IP, Modbus Gateway, IEC 61850 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDigital I\/O\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e4 digital inputs, 2 configurable digital outputs, pulse output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eLCD — all measured parameters accessible on-unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eUpdate Rate\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e1 second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eSupply Voltage\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e75–270 V AC \/ 100–380 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eFrequency Range\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e45–65 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eProtection Degree\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eFront panel IP51 \/ Rear IP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eMounting\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eFront panel mount (DIN rail adapter available — EM220 BRACKET, 3068970000)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eDimensions (H × W × D)\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e96 × 96 × 74 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e380 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003e-25 °C to +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eHousing Material\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003ePlastic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eScrew terminal — 0.5–2.5 mm² solid or stranded\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;border-bottom:1px solid #e5e7eb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003eCompliance\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"border-bottom:1px solid #e5e7eb;color:#111827;padding:6px 10px;\"\u003eRoHS compliant (with exemption 7a, 7cI)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth style=\"background-color:#f9fafb;color:#374151;padding:6px 10px;width:42%;\"\u003e\u003cstrong\u003ePart Number\u003c\/strong\u003e\u003c\/th\u003e\n\u003ctd style=\"color:#111827;padding:6px 10px;\"\u003e7760051006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\u003c\/figure\u003e\u003cul style=\"color:#374151;font-family:Arial,sans-serif;font-size:14px;line-height:1.6;margin:0 0 16px;padding-left:20px;\"\u003e\n\u003cli\u003eDual-protocol communication — Modbus RTU over RS485 and Modbus TCP\/IP over Ethernet in a single unit, eliminating the need for a separate protocol converter\u003c\/li\u003e\n\u003cli\u003eBuilt-in Modbus Gateway function bridges existing RS485 devices onto the Ethernet network, simplifying mixed-protocol installations\u003c\/li\u003e\n\u003cli\u003eClass 0.5S active energy accuracy per IEC 62053-22 — suitable for utility-grade sub-metering and billing-quality energy data\u003c\/li\u003e\n\u003cli\u003eCT connection supports primary currents up to 5000 A with standard 1 A or 5 A secondaries\u003c\/li\u003e\n\u003cli\u003e96 × 96 mm front-panel form factor compatible with standard switchboard cutouts — DIN rail bracket also available (3068970000)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Weidmuller","offers":[{"title":"Default Title","offer_id":48960811598072,"sku":"7760051006","price":416.55,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/files\/7760051006_1_763daf3d-4acb-4873-a34a-a6e99a5b565d.jpg?v=1781633010"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0817\/7382\/2200\/collections\/7760051001_1.jpg?v=1780297850","url":"https:\/\/www.tropac.co.nz\/collections\/energy-meters.oembed","provider":"TROPAC","version":"1.0","type":"link"}